| Model | UE-29.9K-T4-HS1 |
|---|---|
| Product Type | Hybrid Inverter |
| Input (Battery) | |
| Battery Type | Li-ion/Lead-acid |
| Battery Voltage Range (Vdc) | 130-850 |
| Full Power Battery Voltage Range (Vdc) | 150-850 |
| Max. Charge / Discharge Power (kW) | 29.9 / 29.9 |
| Rated Battery Voltage (Vdc) | 150 |
| Rated Charge / Discharge Current (A) | 2*100 |
| Max. Charge / Discharge Current (A) | 2*100 |
| Reverse Connect Protection | Yes |
| Communication Interface | CAN/RS485 |
| Input ( PV ) | |
| Max. PV Input Power (kWp) | 59.8 |
| Max. MPPT Current (Per Sring) (A) | 8*20 |
| Max. Isc PV (Per Sring) (A) | 8*30 |
| Max PV (Max. PV Input Voltage) (Vdc) | 1000 |
| MPPT Voltage Range (Vdc) | 150-850 |
| Full Power MPPT Voltage Range (Vdc) | 375-850 |
| Start-up Voltage (Vdc) | 200 |
| Number of MPP Trackers | 4 |
| Strings Per MPP Tracker | 2 |
| Number of PV Input | 8 |
| Max. Inverter Backfeed Current to the Array (A) | 0 |
| Grid AC Input and AC Output | |
| Grid Rated Voltage | 380 / 400 Vac, 3W+N+PE |
| Grid Rated Frequency (Hz) | 50 / 60 |
| Grid Rated Input Active Power (kW) | 29.9 |
| Grid Rated Input Apparent Power (kW) | 29.9 |
| Grid Max. Input Active Power (Grid to Load and BAT) (kW) | 59.8 |
| Grid Max. Input Apparent Power (Grid to Load and BAT) (kVA) | 59.8 |
| Grid Rated Output Active Power (kW) | 29.9 |
| Grid Rated Output Apparent Power | 29.9 |
| Grid Max. Output Active Power (kW) | 29.9 |
| Grid Max. Output Apparent Power (kVA) | 29.9 |
| Grid Rated Input Current (Aac) | 45.4 / 43.2 |
| Grid Max. Input Current (Aac) | 90.8 / 86.4 |
| Grid Rated Output Current (Aac) | 45.4 / 43.2 |
| Grid Max. Output Current (Aac) | 50.3 / 48.1 |
| Grid Power Factor | 0.8 leading to 0.8 lagging |
| Grid Input and Output Inrush Current | 500A a.c. @10ms |
| Max. Grid Output Fault Current | 500A a.c. @10ms |
| Max. Grid Output Overcurrent Protection | 68.1/64.7A a.c.@ 0.2s |
| Grid Input Icc (Rated Conditional Short-Circuit Current) (A ac) | 500 |
| Grid Input Icw (Rated Short-time Withstand Current) (A ac) | 500 |
| Total Harmonic Distortion(THDi, Rated Power) | <3% |
| EPS Rated Output Voltage | 380 / 400 Vac, 3W+N+PE |
| EPS Rated Output Frequency (Hz) | 50/60 |
| EPS Rated Output Active Power (kW) | 29.9 |
| EPS Rated Output Apparent Power (kVA) | 29.9 |
| EPS Max. Output Active Power (kW) | 32.9 |
| EPS Max. Output Apparent Power (kVA) | 32.9 |
| EPS Rated Output Current (A) | 45.4 / 43.2 |
| Overload (Off Grid) | 110% 30s / 120% 10s / 150% 0.2s |
| Max. Output Current (A) | 50/47.5 |
| EPS Output Power Factor | 0.8 leading to 0.8 lagging |
| EPS Output Peak Power (kVA) | 44.9(<0.2s) |
| EPS Output Inrush Current | 500A a.c.@ 10ms |
| EPS Max. Output Fault Current | 500A a.c.@ 10ms |
| EPS Max. Output Overcurrent Protection (A) | 68.1/64.7 |
| Switch Time | <20ms |
| Total Harmonic Distortion(THDv, Linear Load) | <3% |
| Compatible with The Generator | Optional |
| Battery Module | HB2-10kWh-N |
| Rated Battery Voltage (V) | 32 |
| Battery Configuration | 10S1P |
| Capacity (Ah) | 314 |
| Module Energy (kWh) | 10.05 |
| Cycle Life | 6000 cycles @ 80% SOH |
| Battery Auto Wake-up | Yes |
| Battery System | 6 batteries |
| System Energy (kWh) | 60.3 |
| Rated Battery Voltage (V) | 192 |
| Number of Battery Modules | 6 |
| Max. Charge / Discharge Current (A) | 200 |
| System Dimensions (W×D×H) (mm) | 880x298x1690 (Maximum stacking height: 6 layers) |
| Control Box Dimensions (WHD) (mm) | 880x298x160 |
| Base & Upper Cover (WHD) (mm) | 880x298x 100 |
| General Parameter | |
| Installation | Floor-mounted |
| Efficiency | |
| MPPT Efficiency | 0.999 |
| Euro-Efficiency | 0.975 |
| Max.Efficiency | 0.98 |
| Standard | |
| Safety | EN/IEC 62109-1 / 2, EN/IEC 62477-1 |
| EMC | EN IEC 61000-6-1/3 |
| Grid-Interactive | VDE V 0124-100, VDE-AR-N 4105, EN 50549-1/10 |
| Battery System | EN 62477-1, VDE-AR-E 2510-50, EN/IEC62477-1,IEC62619, ISO13849-1, UN38.3 |
| Degree of Ingress Protection | IP66 |
| Protection Class | I |
| Environment Category | Outdoor |
| Wet Location Classification | Yes |
| Pollution Degree | PD3 |
| Operating Altitude | 4000 m(>2000m Derating) |
| Operating Ambient Temperature | -25 - +60℃ (linely derating to 60% when exceed +45 to +60℃) Charge: -20 - +50℃ Discharge: -20 - +55℃ |
| Operating Relative Humidity | 0-100% (non-condensing) |
| Storage Temperature | -25- +60℃ |
| Storage Relative Humidity | 0-95% (non-condensing) |
| Noise Emission(typical) (dB) | <65 |
| OvervoltageCategory | AC:III, PV:II |
| Electrical Supply System | TN, TT |
| Dimension (WxHxD)(Inverter) | 544880278mm |
| Net Weight(Inverter) | 88kg |
| Cooling Mode | Intelligent Air Cooling |
| Topology | Non-isolated |
| Active Anti-islanding Method | Active frequency drift |
| Communication | RS485 / WiFi / Bluetooth / LAN / CAN / DRM/ Meter Yes/ Yes/ Opt/Opt/ Yes/ Yes/ Opt |